ECKLUND-HARRISON TECHNOLOGIES, INC.
11000/38 Metro Parkway -- Fort Myers, FL 33912 -- USA
Telephone (941) 936-6032 | FAX (941) 936-6327

Process Simulator & Rotating Retort Equipment


  • ESRA (Ecklund Slip Ring Assembly): Several Types of agitating retorts require the use of multiple circuit slip ring assemblies at the end of a rotating shaft to conduct thermocouple signals froma rotating to stationary mode. Such devices can be very troublesome if foreign metals (not thermocouple metals) are part of the circuit and/or temperature differentials exist across the slip ring assembly. In our opinion, it is best to build the slip ring assembly using thermocouple materials in the conductive circuits and isolate the assembly fromt he end of the hot retort shaft to minimize temperature differentials.
    The Ecklund Slip Ring Assembly is designed to provide isolation from temperature differentials and is built of compensating materials for type "T" (coppper-contantan) thermocouples. The rotor shaft is mounted on sealed ball bearings to eliminate any problem of binding.
    Though the sixteen (16) circuit unit is considered standard, we can provide the Slip Ring Assembly with from Six (6) to thirty-two (32) circuits. The design of the unit permits installation on virtually any style of rotating retort with minimum difficulty.
  • ESR-HUB: This is an eighteen (18) circuit "hub" for installation on the FMC Steritort. The unit comes with eighteen (18) S-31's mounted in the hub. This permits the use of upt o 18 rotary leads instad of the standard six (6).
    The design incorporates a one and one-quarter (1 1/4) inch NPT stainless steel pipe nipple which threads into the shaft of the FMC Steritort.
  • S-28 ROTARY CONTACTOR: For use in conducting heat penetration tests in rolling cans in FMC Steritorts. The rotating parts are small in diameter to reduce frictional torque. The rotor may be removed for cleaning by removing a snap ring. No adjustments are necessary on re-assembly. The contactor is supplied with a 34 inch (0.86 meters) wire and locking connector to connect into the hub of the Steritort, and can be used with any style Ecklund thermocouple, but CNS and C-2 types are recommended.
  • S-28 NR: A Rotary Receptacle for use in FMC Steritorts. This unit was designed to eliminate the problem of intermittent signal in monitoring cans in the rotating mode. May not be suitable for use with "conventional" closing equipment. A thermocouple is supplied with the unit. Please specify the can height.


Back to Home
   
       

ESRA SLIP RING ASSEMBLY

ESR-HUB

   


S-28 ROTARY CONTACTOR


S-28 NR