ECKLUND-HARRISON TECHNOLOGIES,
INC. 11000/38 Metro Parkway -- Fort Myers,
FL 33912 -- USA Telephone (941) 936-6032 | FAX (941) 936-6327
Process
Simulator & Rotating Retort
Equipment
- ESRA (Ecklund
Slip Ring Assembly): Several Types of agitating retorts require the use of multiple
circuit slip ring assemblies at the end of a rotating shaft to conduct
thermocouple signals froma rotating to stationary mode. Such devices can
be very troublesome if foreign metals (not thermocouple metals) are part
of the circuit and/or temperature differentials exist across the slip
ring assembly. In our opinion, it is best to build the slip ring
assembly using thermocouple materials in the conductive circuits and
isolate the assembly fromt he end of the hot retort shaft to minimize
temperature differentials.
The Ecklund Slip Ring
Assembly is designed to provide isolation from temperature differentials
and is built of compensating materials for type "T" (coppper-contantan)
thermocouples. The rotor shaft is mounted on sealed ball bearings to
eliminate any problem of binding. Though the sixteen (16)
circuit unit is considered standard, we can provide the Slip Ring
Assembly with from Six (6) to thirty-two (32) circuits. The design of
the unit permits installation on virtually any style of rotating retort
with minimum difficulty.
- ESR-HUB:
This is an eighteen (18) circuit "hub" for installation on the FMC
Steritort. The unit comes with eighteen (18) S-31's mounted in the hub.
This permits the use of upt o 18 rotary leads instad of the standard six
(6).
The design incorporates a one and one-quarter (1 1/4) inch NPT
stainless steel pipe nipple which threads into the shaft of the FMC
Steritort.
- S-28 ROTARY
CONTACTOR:
For use in conducting heat penetration tests in rolling cans in FMC
Steritorts. The rotating parts are small in diameter to reduce
frictional torque. The rotor may be removed for cleaning by removing a
snap ring. No adjustments are necessary on re-assembly. The contactor is
supplied with a 34 inch (0.86 meters) wire and locking connector to
connect into the hub of the Steritort, and can be used with any style
Ecklund thermocouple, but CNS and C-2 types are recommended.
- S-28
NR: A Rotary
Receptacle for use in FMC Steritorts. This unit was designed to
eliminate the problem of intermittent signal in monitoring cans in the
rotating mode. May not be suitable for use with "conventional" closing
equipment. A thermocouple is supplied with the unit. Please specify the
can height.